Cooling Machine

Product Details
Customization: Available
After-sales Service: Technical Support
Warranty: One Year Warranty
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (14)
  • Cooling Machine
  • Cooling Machine
  • Cooling Machine
  • Cooling Machine
  • Cooling Machine
  • Cooling Machine
Find Similar Products
  • Overview
  • Product Description
  • Main structure and principle
  • Detailed Photos
  • Product Parameters
  • Main Features
  • Workshop
Overview

Basic Info.

Model NO.
DL-15
Type
Water-Cooled
Cooling Water
Industrial Water
System Type
Roller
Fans Species
No
Noise Level
Low
Application Fields
Machinery
Certification
CE
Condition
New
Output
15t/H
Length
8200mm
Cooling Water Capacity
50-60m3/H
Cooling Water Pressure
0.2-0.6MPa
Cooling Water Quality
Demineralized Water
Motor Power
11kw
Weight
15t
Voltage
220V/380V/415, etc.
Inlet Water Temperature
20-30 Degree
Outlet Water Temperature
50-90degree
Inlet Slag Temperature
800-1000degree
Outlet Slag Temperature
60-80degree
Payment
T/T,50%Deposit in Advance and 50% Balance Before S
Shipping
Container by Sea
Customerized
Support
Transport Package
Nude
Specification
10T
Trademark
Dong Lai
Origin
China
HS Code
8418692090
Production Capacity
500 Sets/Year4

Product Description

Multi-tube slag cooler
Cooling Machine
Product Description

It absorbs the advantages of similar products at home and abroad, continuously innovates and improves, and solves a series of problems such as frequent maintenance and cost of slag coolers, water leakage and slag blocking, high slag discharge temperature, and short service life that exist in similar products. It can effectively ensure the continuous and stable operation of the equipment. It is a slag cooler produced by the technology of double-spiral heat fins and solid-welded cold slag heat exchange tubes.
 

Main structure and principle

Main structure:
 This product adopts a parallel multi-channel split cooling method, which consists of a feeding chamber, a discharging chamber, a driving device, a plurality of cooling and heat exchange tubes, a rotating simplified structure, a frame and other parts.

Working principle:
 The boiler slag drop pipe is directly connected to the slag inlet of the machine. During operation, the cylinder is driven by the driving device to run at a low speed, and the inlet and outlet valves are opened at the same time, so that the cooling water (about 30°C) fills the cylinder and maintains a certain flow. The high-temperature slag enters each cooling channel uniformly through the feeding chamber, and the cooling channel is provided with spiral heat-absorbing fins, which play a driving role. The slag travels a certain distance in the cooling channel every time it rotates. With the continuous rotation of the simplifier, the slag and the cooling water flow through each heating surface in the opposite direction for heat exchange, so that the temperature of the slag is lowered, and the hot water enters the deaerator.

Detailed Photos

 

Cooling Machine
Cooling Machine
 
Product Parameters
Model DL2-3 DL4-5 DL6-8 DL10-12
Output(T\h) 2-3 4-5 6-8 10-12
(°C)Inlet slag temperature 800-1000 800-1000 800-1000 800-1000
(°C)Outlet slag temperature 60-80 60-80 60-80 60-80
(°C)Inlet water temperature 20-30 20-30 20-30 20-30
(°C)Outlet water temperature 50-90 50-90 50-90 50-90
(Mpa)Water pressure 0.3-2.0 0.3-2.0 0.3-2.0 0.3-2.0
(m³)Water volume 6 12 18 24
(r\Min)Rated speed 4 4 4 4
(KW)Rated power 1.1 1.5 2.2 3
Water quality   Demineralized water
 
Main Features
1. Large heat exchange area, low temperature waste slag discharge. This feature can greatly absorb the heat in the slag, so that it can be returned to the system to generate direct economic benefits, and at the same time, the slag can be reduced to below 100 degree, which can provide a wider range of options for the slag conveying method.
2. Small wear and long service life. In order to reduce wear and tear, the design is divided into high and low temperature sections, and the spiral heat sink in the high temperature section is made of ICr18Ni9Ti material. Because the spiral action slag can only roll toward the outlet according to the trajectory of the spiral blade, there is rolling friction between the slag particles and the inner wall of the metal. In addition, the linear velocity of the inner wall of the tube is low and the wear is small, so the service life is greatly extended. Small size, easy to install.
3. Due to the reasonable slag discharge process, the heat transfer coefficient is high, and the volume is small when the slag discharge temperature is low in the same industry. The equipment is installed horizontally (0-3° inclined installation can also be carried out according to customer requirements), which is suitable for the space requirements of the site and is conducive to installation. The boiler is changed from regular slag discharge to continuous slag discharge.
4. The product adopts frequency conversion control device, which can realize automatic control, and can adjust the drum speed according to the amount of slag, so that the speed can be adjusted at any time according to the change of boiler load, so as to keep the coal supply and slag discharge of the boiler in balance, thus maintaining the boiler fire bed. The stability of the material layer thickness further reduces the loss of mechanical incomplete combustion and chemical incomplete combustion for the boiler, which has direct benefits.

 
Cooling Machine
Cooling Machine
 
Cooling Machine
Cooling Machine

 

Cooling Machine
Cooling Machine
 
Workshop
Cooling Machine
Cooling Machine

 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier